What We Do
Three Services.
One Partner.
From the first audit to ongoing maintenance and certified installation, AJC Fire Stopping manages the entire fire door compliance process in-house. No handoffs. No gaps.

01
A certified inspection of every fire door set, covering gaps, seals, ironmongery, self-closers, glazing, and frame integrity. Each report includes clear written findings, photographic evidence, and a prioritised action plan suitable for regulators and insurers.
Door-by-Door Schedule
Complete inventory with individual pass/fail status, defect notes and gap measurements
Photographic Evidence
Every defect is photographed and clearly referenced, providing evidence for audits and enforcement.
Prioritised Action Plan
Defects ranked Critical / Advisory / Recommended so you act in the right order
Compliance Certificate
Signed certificate confirming inspection to FSO 2005, BS 8214 and BS 9999
Automatic Reminders
You’ll receive an automatic reminder 30 days before your next audit is due, giving you time to schedule it in advance.

Door leaf, frame & wall integrity
Structural assessment against BS 8214 and BS 9999 requirements
Gap measurements & threshold
All gaps and thesholds precision-measured
Intumescent & cold smoke seals
Integrity, damage and specification checked against door rating
Self-closers, hinges & ironmongery
CE-marked components verified for condition and correct operation
Fire safety signage & glazing
Signage clarity and fire-rated glazing integrity confirmed
Sample Output
What A Report Looks Like
Each door has its own record showing pass or fail status, measured gaps, component condition, and any required remedial actions. The records are structured to meet the needs of regulators, insurers, and your fire risk assessment.
Available as PDF and digital format
Inspector certification details included
Shareable with insurer or fire authority
Door 001 — Ground Floor Lobby
PASS
Door 002 — 1st Floor Stairwell
FAIL — ACTION
Door 003 — Plant Room
PASS
Door 004 — 2nd Floor Corridor
ADVISORY
Door 005 — Rear Exit
FAIL — URGENT
Door 006 — Reception
PASS
Inspector: AJC FS Certified
BM Trada Q-Mark
Your Legal Requirement
Who needs fire door audits, and how often
Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person for any non-domestic building must ensure fire doors are regularly inspected and maintained. The Fire Safety (England) Regulations 2022 require communal fire doors in residential blocks over 11 metres to be inspected every three months, and flat entrance doors annually. Non-compliance can result in prosecution, unlimited fines, or imprisonment.
02
Maintenance
& Repair
We fix defects using certified components to manufacturer specification. Whether from an audit finding or a routine service visit, every repair is documented and added to your compliance record.
Service Contracts
Ongoing scheduled maintenance, we manage the calendar, you maintain compliance
Remediation First
We repair before replacing, saving cost while maintaining full compliance
Full Documentation
Every repair recorded with date, component, technician and photographic evidence

Intumescent Seal Replacement
Certified strip matched to door rating
COMPLETE
Self-Closer Adjustment
Positive latch confirmed on every closure
COMPLETE
Hinge Replacement
CE-marked to BS EN 1935, correctly installed
CERTIFIED
Gap Correction
Frame adjusted to 3mm tolerance
COMPLETE
Cold Smoke Seal
Integrity verified and replaced
CERTIFIED
Repair Coverage
What We Fix
Every component of a fire door assembly contributes to its fire resistance. A single failed component can compromise an otherwise compliant door.
Self-closing Devices
Adjustment, replacement and testing, positive latching on every closure, every time
Intumescent Seals
Replacement with certified strips matched to the door's rated fire resistance
Cold Smoke Seals
Prevents smoke spread before heat activates intumescent, first line of defence
Hinges & Ironmongery
CE-marked replacements installed to BS EN 1935, the specification that matters in a fire
Gap Correction
Frame and leaf adjustment to bring all gaps within regulatory tolerance
Glazing & Apertures
Certified fire-rated glazing checked and replaced where integrity is compromised
03
Fire Door
Installation
New and replacement fire door sets, FD30 and FD60, supplied and installed by certified technicians. Every installation is fully documented with a completion certificate, ready for your compliance file from day one.
New Build & Retrofit
Structural adjustments handled to achieve correct tolerances in any opening
Heritage & Listed Buildings
Sympathetic solutions, fire performance without compromising architectural character
Completion Certificate
Every installation signed off with a certificate and photographic evidence, valid from day one

FD30
30-Minute Fire Resistance
Standard compartmentation for corridors, offices, education and commercial spaces
✓
Certified door set & ironmongery
✓
Intumescent & cold smoke seals
✓
Self-closer installed and tested
FD60
60-Minute Fire Resistance
Higher-risk areas, plant rooms, high-rise, protected escape routes
✓
Enhanced fire resistance rating
✓
Completion certificate day one
✓